Three Phase Autotransformer Connections

Three Phase Transformer Connections A three-phase transformer is built for a specific connection and voltage transformation and the unit will have a nameplate with the internal connections shown.

Want create site? Find Free WordPress Themes and plugins.
  • The CTA three phase autotransformers are constructed in accordance with EN 60726 as applicable and approved UL/CSA File E309790. During the design and engineering of ‘Autotransformer CTA was held particularly highlighted the problem of reducing the size of footprint.
  • 3 Phase Step Up Transformer 240 to 480 Wiring Diagram– wiring diagram is a simplified pleasing pictorial representation of an electrical circuit.It shows the components of the circuit as simplified shapes, and the capability and signal contacts in the company of the devices.

In this section, we’ll review the operating characteristics of basic delta-delta, wye-wye, delta-wye and wye-delta connections of the transformer.

The construction of a three-phase transformer can be represented as shown in Figure 1. The shell type core has three sets of primary and secondary windings. How these windings are connected together determines the configuration of the transformer (delta, wye, etc).

Figure 1: Three-Phase Transformer Construction

Wye-Wye (Y-Y) Connected Transformer

The transformer in Figure 1 can be represented as shown in Figure 2. T1, T2, and T3 represent the same three primary/secondary coil pairs shown on the shell type core. The lines labeled ΦA1, ΦB1 and ΦC1 represent primary line conductors that connect to the primary coils, and the line labeled N1 represents a neutral conductor. Likewise, the lines labeled ΦA2, ΦB2 and ΦC2 represent secondary line conductors and N2 represents a neutral conductor.

Figure 2: Elements of a transformer wiring diagram.

When wired as shown in Figure 3, the shell type transformer forms a Y-Y (wye-primary-wye secondary) circuit. As such, the transformer primary and secondary current and voltage relationships are as follows:

$begin{matrix}{{E}_{L}}=sqrt{3}times {{E}_{P}}=1.732times {{E}_{P}} & {} & {{I}_{L}}={{I}_{P}} end{matrix}$

$begin{matrix}{{E}_{P}}=frac{{{E}_{L}}}{sqrt{3}}=frac{{{E}_{L}}}{1.732} & {} & {{I}_{N}}={{I}_{A}}+{{I}_{B}}+{{I}_{C}}=0 end{matrix}$

Where EL and IL are the line values, and EP and IP are phase values. These relationships assume that the Y-Y circuit is balanced (Before reading on, take a moment to trace out the circuit connections in Figure 3 to verify that the diagram represent the same circuit).

Figure 3: Y-Y transformer Schematic & Wiring Diagram

There are two points to be made:

• The wiring diagram in Figure 3a can be made implemented using a bank (group) of three single phase (1Φ) transformers.

• Y-Y Transformers are used in industrial applications and are preferred over ∆-∆ transformers when it is critical to have a neutral connection in the secondary circuit.

  • You May Also Read: Three Phase Transformer Connections Phasor Diagrams

Delta-Delta (∆-∆) Connected Transformer

When wired as shown in Figure 4, the shell type transformer forms a ∆-∆ (delta primary-delta secondary) circuit. Note that there is no neutral line in the wiring diagram. The transformer, primary and secondary current, and voltage relationships are as follows:

$begin{matrix}{{E}_{L}}={{E}_{P}} & {} & {{I}_{L}}=sqrt{3}times {{I}_{P}}=1.732times {{I}_{P}} end{matrix}$

$begin{matrix}{{I}_{P}}=frac{{{I}_{L}}}{sqrt{3}}=frac{{{I}_{L}}}{1.732} & {} & {{I}_{N}}={{I}_{A}}+{{I}_{B}}+{{I}_{C}}=0 end{matrix}A$

Where EL and IL are line values, and EP and IP are phase values. These relationships assume that the ∆-∆ the circuit is balanced (Before reading on, take a moment to trace out the circuit connections in Figure 4 to verify the diagrams represent the same circuit).

Figure 4: Delta-Delta (∆-∆) Transformer Schematic & Wiring diagrams.

As was the case with the Y-Y circuit, the wiring diagram in Figure 4a can be implemented using a bank of single-phase transformers. Note that ∆-∆ transformers are most commonly found in Industrial applications.

Wye-Delta (Y-∆)Connected Transformer

When wired as shown in Figure 5, the shell type transformer forms a Y-∆ (wye primary-delta secondary) circuit. Note that there is a neutral connection in the primary circuit, but none in the secondary circuit. (Before reading on, take a moment to trace out the circuit connections in Figure 5 to verify that the diagrams represent the same circuit).

Figure 5 Wye-Delta (Y-∆) transformer Schematic & Wiring diagrams.

As was the case with the previous circuits, the wiring in the diagram in Figure 5a can be (and often is) implemented using a bank of single phase (1Φ) transformer. Note that Y-∆ connected transformers are most commonly used in high voltage transmission system.

Delta-Wye (∆Y) Connected Transformer

When wired as shown in Figure 6, the shell type transformer forms ∆-Y (delta primary-wye secondary) circuit. Note that there is a neutral connection in the secondary circuit, but none in the primary circuit. (Before reading on, take a moment to trace out the circuit connections in Figure 6 to verify that the diagram represents the same circuit).

Autotransformer

Figure 6 (Delta-Wye )∆-Y transformer Schematic & Wiring Diagram

As was the case with the previous circuits, the circuit in Figure 6a can be implemented using a single phase (1Φ) transformers. Note that ∆-Y connected transformers are most commonly found in commercial and industrial applications.

Why Using Single Phase Transformer Banks?

As mentioned earlier, each transformer introduced in this section can be constructed using a bank (group) of single-phase transformers. Such a transformer bank is shown in Figure 7.

Transformer

Autotransformer Grounding

Figure 7 Three single-phase transformers wired as a three-phase transformer bank

Why use three single phase transformer banks in place of a single three-phase transformer? Two reasons: convenience and practicality.

The most common failure in any three-phase system is a grounding fault where one phase fails (shorts) to ground. When a single three-phase transformer is being used, the failure of one phase necessitates replacement of the entire transformer. However, when a bank of single-phase transformers is used, the failure of any phase requires the replacement of that phase transformer only; and it is easier and cheaper to replace a single phase transformer than a three-phase transformer.

Also, a group of three single phase transformers can be wired as any of the connections that were introduced in this section. Three phase transformers are manufactured in specific configurations, and therefore do not have this flexibility.

Open Phases in Three Phase Transformers

When one of the phase inductors in a wye-connected circuit opens, the entire circuit is effectively reduced to a single-phase circuit. This principle is illustrated in Figure 8a. When L1 opens, ΦA is isolated from the circuit. When this occurs, there is no current through L1 and only EBC is unchanged. In effect, the three-phase circuit has been reduced to a single phase circuit.

Figure 8 Wye (Y) and Delta( ∆) circuit voltages.

When one of the phase inductors in a delta connected circuit opens, the circuit still operates as a three-phase circuit (at reduced capacity). This principle is illustrated in Figure 8b. When L1 opens, none of the phase inputs is isolated from the circuit, so three-phase operation continues. However, there is no current through L1, which does affect the overall operation of the delta circuit. The kVA rating of the transformer is reduced because the power handling capacity of L1 is reduced to 0W. Even so, the circuit can continue three-phase operation at reduced opacity.

Open Delta Connection

As stated earlier, a delta connected transformer can operate at a reduced capacity if one of its phases opens. This principle makes it possible to produce a three-phase circuit using only two single-phase transformers. This Open Delta Connection, which is rarely encountered anymore, is shown in Figure 9.

Note that the kVA rating of an open delta connection is limited to approximately 87% of the sum of the nameplate kVA ratings of the two single-phase transformers. For example, if each transformer has a rating of 100kVA, then the kVA rating of the open delta bank is 200KVA × 87% = 174 kVA. This is due to the fact that only two transformers are carrying the load of three.

Figure 9 Open-delta transformer Schematic & Wiring Diagram

Did you find apk for android? You can find new Free Android Games and apps.
Three phase transformer connectionsIn three phase system, the three phases can be connected in either star or delta configuration. In case you are not familiar with those configurations, study the following image which explains star and delta configuration. In any of these configurations, there will be a phase difference of 120° between any two phases.

Auto Transformers Three Phase

Three phase transformer connections

Windings of a three phase transformer can be connected in various configurations as (i) star-star, (ii) delta-delta, (iii) star-delta, (iv) delta-star, (v) open delta and (vi) Scott connection. These configurations are explained below.

Star-star (Y-Y)

  • Star-star connection is generally used for small, high-voltage transformers. Because of star connection, number of required turns/phase is reduced (as phase voltage in star connection is 1/√3 times of line voltage only). Thus, the amount of insulation required is also reduced.
  • The ratio of line voltages on the primary side and the secondary side is equal to the transformation ratio of the transformers.
  • Line voltages on both sides are in phase with each other.
  • This connection can be used only if the connected load is balanced.

Delta-delta (Δ-Δ)

  • This connection is generally used for large, low-voltage transformers. Number of required phase/turns is relatively greater than that for star-star connection.
  • The ratio of line voltages on the primary and the secondary side is equal to the transformation ratio of the transformers.
  • This connection can be used even for unbalanced loading.
  • Another advantage of this type of connection is that even if one transformer is disabled, system can continue to operate in open delta connection but with reduced available capacity.

Star-delta OR wye-delta (Y-Δ)

  • The primary winding is star star (Y) connected with grounded neutral and the secondary winding is delta connected.
  • This connection is mainly used in step down transformer at the substation end of the transmission line.
  • The ratio of secondary to primary line voltage is 1/√3 times the transformation ratio.
  • There is 30° shift between the primary and secondary line voltages.

Three Phase Autotransformer Connections Wiring

Delta-star OR delta-wye (Δ-Y)

  • The primary winding is connected in delta and the secondary winding is connected in star with neutral grounded. Thus it can be used to provide 3-phase 4-wire service.
  • This type of connection is mainly used in step-up transformer at the beginning of transmission line.
  • The ratio of secodary to primary line voltage is √3 times the transformation ratio.
  • There is 30° shift between the primary and secondary line voltages.
Above transformer connection configurations are shown in the following figure.

Open delta (V-V) connection

Two transformers are used and primary and secondary connections are made as shown in the figure below.Open delta connection can be used when one of the transformers in Δ-Δ bank is disabled and the service is to be continued until the faulty transformer is repaired or replaced.It can also be used for small three phase loads where installation of full three transformer bank is un-necessary.The total load carrying capacity of open delta connection is 57.7% than that would be for delta-delta connection.

3 Phase Auto Transformer Connections

Scott (T-T) connection

Two transformers are used in this type of connection. One of the transformers has centre taps on both primary and secondary windings (which is called as main transformer). The other transormer is called as teaser transformer.Scott connection can also be used for three phase to two phase conversion.The connection is made as shown in the figure below.

Three Phase Transformer Pdf